Determine ESD Targets:

                   Rv =  0.05 +0.009(I)
                      =  0.48

                   From Table 5.3 and        HSG        A        B        C       D
                   %I =  48                  Area                                90,272
                                                                                  1.8
                                           Target P E
                                        Composite Target P E  (in.):     1.80

                 ESDv =  (P E )(Rv)(A)
                            12
                      = 6,550    cf

            Step 2 - Preliminary ESD Options

                   Please refer to the Stormwater Management Report

            Step 3 - ESD  Design
                   Evaluation of specific ESD treatment practices for the project on the following sheets.