Page 60 - planning-committee-packet
P. 60
INDEX OF SHEETS PLANS ISSUED FOR:
General Notes: SHEET N o TABLE OF CONTENTS Review
1.) Horizontal Datum: Maryland State Plane NAVD88 C 001 TITLE SHEET REVISIONS:
2.) Contour Interval is 1 foot. SOUTH MOON UNDER C 100 EXISTING CONDITIONS
3.) Contractor shall be responsible for obtaining all required permits for the C 101 No. Revision/Issue: Date
work indicated. SITE PLAN
4.) The contractor shall satisfy himself as to all site conditions prior to C 102 GRADING PLAN
bidding and construction. C 103 IMPERVIOUS AREA EXHIBIT
5.) Contact Miss Utility (1-800-441-8355) for existing utility locations 48 619 FRANKLIN AVENUE, TOWN OF BERLIN C 104 EROSION AND SEDIMENT CONTROL PLAN
hours prior to commencing work. C 105 EXISTING DRAINAGE AREAS
6.) Contractor shall be responsible for the coordination of construction C 106 PROPOSED DRAINAGE AREAS
efforts with utility companies/ providers, and others as may be WORCESTER COUNTY, MARYLAND C 107 STORMWATER MANAGEMENT PLAN
required.
C 108 LANDSCAPE PLAN
7.) All utility and survey data shown on the drawings have been provided C 109 LAYOUT PLAN
by the Atlantic Group & Associates, Inc.. Information has been FINAL PLAN
obtained from the best available sources at the time of the survey, but C 500 DETAILS
is not represented as being complete and accurate. It is the C 501 DETAILS
contractor's responsibility to locate and protect existing utilities and C 502 DETAILS
underground structures. Damage to existing utilities and underground C 503 DETAILS
structures shall be repaired by the contractor at no additional cost to C 504 DETAILS
the developer. C 505 DETAILS
8.) The contractor shall re-establish all property pins, monuments, water
meters, drainage culverts, fences, utility poles, driveways, curbs, All phases of stormwater management calculations, structure design and construction will
gutters, etc. disturbed during construction at no additional cost to the adhere to current Town of Berlin Code and Stormwater Ordinance, Maryland standards and
developer. specifications for stormwater management and stormwater management plan for this site.
9.) All disturbed areas, shall be repaired to a condition equal to or better All information set forth in these plans accurately conveys this site's conditions to the best of
than those existing prior to construction, or as shown on the drawing. my knowledge.
10.) The contractor shall use only new materials, parts and products. All
materials shall be stored so as to assure the preservation of their I HEREBY CERTIFY THAT THE STORMWATER MANAGEMENT FACILITIES All structural devices for strowmater management will be protected by proper soil erosion
quality and fitness for the work. (BOTH BMPS AND ESD PRACTICES) SHOWN ON THE PLANS HAVE BEEN and sediment control devices until all contributing areas have passed final stabilization
11.) Should unsuitable material be encountered during construction of the inspection.
utilities, roadways, parking lots, and building pads, it shall be the CONSTRUCTED IN ACCORDANCE WITH THE PLANS APPROVED BY THE
contractor's responsibility to remove the unsuitable material and MARYLAND DEPARTMENT OF THE ENVIRONMENT, EXCEPT AS NOTED IN Upon completion of the project, an as-constructed survey, Notice of Construction Completion
(NOCC), and letter of certification must be submitted to the Town, except individual single
replace it with suitable material. The contractor shall be responsible for RED ON THE "AS-BUILT" DRAWINGS. family dwellings. Once review is complete and approved, a certificate of occupancy can be
importing select material if on-site suitable material is not available. issued.
Cost for the actual imported material shall be the owners/ developers SOUTH MOON UNDER TOWN OF BERLIN WORCESTER COUNTY, MARYLAND
responsibility.
12.) Any subsequent revisions, additions, and/or deletions shall require
specific written approval of the owner.
13.) Any discrepancies with the plans and site conditions shall be brought to
the immediate attention of the engineer. SITE NAME SIGNATURE
14.) The absence of the developer or the engineer at the job site does not,
in any way, relieve the contractor of the responsibility to perform the
work in accordance with the drawings, contract documents, addenda,
and written authorized plan revision.
15.) The contractor shall comply with all applicable laws, ordinances, rules,
regulations, and orders of any body having jurisdiction. The contractor MARYLAND REGISTRATION DATE
shall erect and maintain, as required by the conditions and progress of
the work, all necessary safeguards for safety and protection. NUMBER
16.) Any additional utilities to be relocated shall be relocated at the owners/
developers expense, including utilities within public right-of-way.
FACILITIES BERING CERTIFIED:
PROJECT LOCATION NOT TO SCALE SGW-1
SGW-2
i il n ineers an lanners
CONSULTANTS an scape Arc itects
EX. ELECTRIC POLE EX. UTILITY POLE E PR. ELECTRIC POLE DIRECTIONAL FLOW ARROW OWNER: ur e ors
EXISTING CONCRETE
EX. ELECTRIC CONDUIT EX. LIGHT POLE (GLOBE STYLE) PCDT PR. ELECTRIC CONDUIT PIPE FLOW DIRECTION ARROW
EX. ELECTRIC MANHOLE EX. LIGHT POLE (COBRA STYLE) E PR. ELECTRIC MANHOLE PROPOSED WHEELSTOP
EXISTING WETLANDS NEEV PROPERTIES, LLC
EX. ELECTRIC METER EX. SIGN EM PR. ELECTRIC METER PROPOSED HANDICAP PARKING
31236 MEADOWVIEW SQUARE
EX. ELECTRIC BOX EX. FLAG POLE EB PR. ELECTRIC BOX PROPOSED SWALE
GRAVEL
EX. ELECTRIC TRANSFORMER EX. TREE ET PR. ELECTRIC TRANSFORMER PROPOSED SWALE T.O.B. DELMAR, DE 19940 10044 Old Ocean City Boulevard Berlin, Maryland 21811 Ph: (410) 629-1160 Fax: (410) 629-1710 www.the-atlanticgrp.com
EX. OVERHEAD ELECTRIC EX. HANDICAP PARKING/RAMP PR. OVERHEAD ELECTRIC PROPOSED GRAVEL WETLANDS Atlantic Group
PROPOSED PAVEMENT
EX. UNDERGROUND ELECTRIC EX. FINISHED FLOOR ELEVATION PR. UNDERGROUND ELECTRIC SF SILT FENCE SURVEYOR, PLANNER, CIVIL ENGINEER,
EX. CABLE TV PEDESTAL EX. FENCE TV PR. CABLE TV PEDESTAL LOD LIMIT OF DISTURBANCE LANDSCAPE ARCHITECT: & Associates, Inc.
PROPOSED CONCRETE
EX. TELEPHONE MANHOLE EX. WHEELSTOP T PR. TELEPHONE MANHOLE SF- SILT FENCE &
LOD LIMIT OF DISTURBANCE
EX. TELEPHONE PEDESTAL SPOT GRAVEL TP PR. TELEPHONE PEDESTAL Atlantic Group & Associates, Inc.
RIP RAP SSF/ SUPER SILT FENCE &
EX. UNDERGROUND TELE. SPOT CONCRETE PR. UNDERGROUND TELE. LOD LIMIT OF DISTURBANCE
10044 Old Ocean City Boulevard
EX. UNDERGROUND VERIZON SPOT ASPHALT PR. UNDERGROUND VERIZON PROPOSED DRAINAGE BOUNDARY
STORMWATER MANAGEMENT Berlin, MD 21811
EX. OVERHEAD COMM. SPOT GRASS PR. OVERHEAD COMM.
GV Ph: (410) 629-1160
EX. GAS VALVE SPOT BRICK PR. GAS VALVE
PR. LARGE TREE
EX. GAS HAND HOLE SPOT WOOD G PR. GAS HAND HOLE
EX. GAS METER SPOT PAVERS GM PR. GAS METER
PR. EVERGREEN TREE
EX. UNDERGROUND GAS LINE SPOT METAL PR. UNDERGROUND GAS LINE
EX. SEWER MANHOLE SPOT PLASTIC S PR. SEWER MANHOLE
PR. LANDSCAPE LABEL
EX. SEWER CLEAN OUT CO PR. SEWER CLEAN OUT
EX. SANITARY SEWER CONCRETE MONUMENT FOUND PR. SANITARY SEWER
EX. STORM DRAIN MANHOLE CONCRETE MONUMENT SET SD PR. STORM DRAIN MANHOLE
EX. STORM DRAIN INLET IRON PIPE FOUND SD PR. STORM DRAIN INLET
PDS
EX. DOWNSPOUT IRON PIPE W/ CAP FOUND PR. DOWNSPOUT
EX. STORM DRAIN PIPE IRON ROD FOUND PR. STORM DRAIN PIPE
EX. WATER MANHOLE IRON ROD W/ CAP FOUND PROPOSED STORM DRAIN INLET
EX. WATER VALVE IRON ROD W/ CAP SET W PR. WATER MANHOLE PROFESSIONAL CERTIFICATION TITLE SHEET
EX. WATER METER SURVEY POINT WV PR. WATER VALVE
SEAL
EX. FIRE HYDRANT BENCHMARK WM PR. WATER METER "I HEREBY CERTIFY THAT THESE DOCUMENTS
WERE PREPARED OR APPROVED BY ME, AND
EX. WELL BOUNDARY LINE P D PR. FIRE HYDRANT THAT I AM A DULY LICENSED PROFESSIONAL
H Y
ENGINEER UNDER THE LAWS OF T HE
EX. WATER ADJOINING LOT LINE W PR. WELL
STATE OF MARYLAND." PROJECT: No. DATE: 12/2/2019
EASEMENT LINE PR. WATER
NAME: JASON A. LINDSEY, P.E.
DRAWN BY: CDD SCALE: NOTED
R.O.W. LINE
LICENSE NO.: 46676 8.13.25 PC Meeting Packet_pg. 55 of 78
EX. DITCH CENTERLINE SHEET:
EXPIRATION DATE: APRIL 29, 20223 C-001